Product Spotlight

72 hour Holter Recordings with MT-101 nano

Posted in Medical News, Product Spotlight by Mat Packer on July 2, 2009 | No Comments

mt-101-nano.jpgThe strengths of Holter ECG monitoring include its simplicity and the lack of need for patient activation. The continuous monitoring allows capture of asymptomatic arrhythmias or arrhythmias associated with loss of consciousness as well as documentation of circadian variation in arrhythmia occurrence.

However the regular 24-hour Holter ECG’s imposed a very limited period of monitoring to a very short window that is often inadequate to diagnose the cause of symptoms.

With SCHILLER’s new MICROVIT MT-101 nano Holter ECG Recorder, you may now monitor your patients heart activity up to 72 hours.

The MT-101 nano Holter Recorder is designed for 2 or 3-channel ECG recordings, depending on the ECG cable you use.

To view and analyse your recorded data you may simply transmit the patients data via integrated USB interface or external SD card reader to any computer, featuring the Medilog Darwin analysis system.

On a very user-friendly Windows Interface, the MT-200 Analysis Software executes the most complicated operations, such as:

  • Analysis of 2 or 3 channels in different combinations
  • ST-Analysis
  • HR Trend overview
  • HR Variability (Fire of Life)
  • Pacemaker Templates
  • Template Matching
  • Reclassification in less than 2 seconds by ‘Drag & Drop’ function

When it comes to administrating and saving your data, the system enables:

  • Generation of PDF files
  • E-mail function
  • Connection to the SCHILLER SEMA-200 Data Management System

Are you interested in trying SCHILLER’s new 72-hour Holter ECG System? Just give us a call and we’ll take care of the rest!

heart-rate-variability.jpg

What makes the FRED easyport so unique?

Posted in Product Spotlight by Mat Packer on July 1, 2009 | No Comments

multipulse-biowave-3.jpgSCHILLER’s unique Multipulse Biowave® is a wave that is pulsed at a high frequency (chopped).

The pulsed wave is made up of two phases, where the current flows in two opposite directions (biphasic) with a fixed duration of 4 ms for each phase, regardless of the patient impedance. That duration has been found to be optimal for the excitation of myocardial cells, maximising the safety and effectiveness of the defibrillation.

Because a second capacitor is used to produce the second phase (negative), the amplitude of the phase is not necessarily identical to that prevalent at the end of the first phase. Consequently, it can be defined freely so as to obtain the amplitude that is best suited to the physiological needs of the heart.

The second phase is sized optimally, and the charges accumulated during the first phase in the myocardial cells can be eliminated completely at the end of the wave. As a result of that elimination, the re-excitation of the unstable cells is prevented, and therefore all the re-entry loops are blocked. The outcome is optimised defibrillation with the least possible energy.

This is how the greatest efficacy can be derived from a biphasic defibrillation wave.

Contact us today for further information and copies of clinical papers on SCHILLER’s unique Multipulse Biowave®.

British NHS evaluate FRED easy AED

Posted in Product Spotlight by Mat Packer on June 2, 2009 | No Comments

Recently the British National Health Service evaluated the FRED easyport defibrillator, and here’s what they had to say about it.

An ideal defibrillator when size and weight are the most important features.

You can download the full report on the SCHILLER FRED easyport AED in PDF format from here.

If you would like to receive further information on the, or any other products in the SCHILLER range, do not hesitate to contact us.

ARGUS Pro Transport

Posted in Product Spotlight by Mat Packer on July 2, 2008 | No Comments

Experience the New Freedom in Intensive Care Monitoring!

The ARGUS PRO Transport II is an intensive care monitor which meets the specific needs of clinics and rescue services. The unit provides full performance for bedside and transport, without restrictions regarding the measured parameters. Suitable for Intensive Care Units, Operating theatres, Recovery rooms, Emergency wards, Ground-, and especially Air Rescue Services.

Features:

  • Small size and low weight
  • Full functionality of the highest capacity Intensive Care Monitoring Systems
  • Intuitive user interface via touch screen
  • Direct access to all important settings of the shown parameters
  • Unlimited number of display configurations can be saved so the display can be adapted to the needs of any monitoring situation
  • As a part of the ARGUS PRO System, the ARGUS PRO Transport II can display the data of any other ARGUS PRO monitor within the clinic network

Options:

  • Resting ECG and FAX
  • Graphical ST analysis
  • Systolic blood pressure variation
  • Cardiac Output